Xhorse Dolphin XP007 Cannot Slide Back and Forth Solution

Problem: I had a problem with my Xhorse dolphin xp007 manual key cutting machine. Can’t slide back and forth, can only spin in circles. Any solution?

Xhorse Dolphin Xp007 Cannot Slide 1

Xhorse Dolphin Xp007 Cannot Slide 2

The workstation (Y direction) cannot slide or shake back and forth solution:

Step 1: Turn the device over. Check if there is something stuck in the sliding gap of the bottom rail.

Xhorse Dolphin Xp007 Cannot Slide 3

If yes, clear dirty stuff

If no, do Step 2.

 

Step 2: Adjust the 2 Kimi screws on the right side against the guide rail, and move the cross slide back and forth. If the cross slide is smooth and not stuck, tighten the 8 screws immediately

Xhorse Dolphin Xp007 Cannot Slide 5

 

NOTE:

Tip: If the 8 screws are loosened, do not tighten the 8 screws immediately. The 2 Kimi screws on the right side need to be adjusted to ensure that the cross slide moves smoothly before tightening the 8 screws.