Xhorse VVDI Prog Failed to Read RENESANS V850 D70F3624 SRS Solution

Problem:
I have a problem with reading SRS Autoliv 624926000 RENESANS – V850_D70F3624 by xhorse vvdi prog programmer. The frequency selection is wrong, the same is manual and auto.
Vvdi Prog RENESANS V850 D70F3624 Srs 1

Vvdi Prog RENESANS V850 D70F3624 Srs 3

Vvdi Prog RENESANS V850 D70F3624 Srs 2

Solution:

1.) Try with older version of software.
3 in row srs modules from Peugeot
read and write without problem with D70F3624.

2). Change tension to lower

3). Incorrect wiring diagram. Check wiring diagram again.

 

 

Feedback:

It works.
Color confused.
Gray in the photo and should be brown.
My oversight but I confirm it works with this MCU.

Vvdi Prog RENESANS V850 D70F3624 Srs 4