Xhorse Digital Multimeter is a practical device that can play an important role in the daily work of locksmiths, making work safer and more convenient. The multimeter supports fast leakage detection without external power supply. Therefore, it is very suitable for friends with remote leakage detection or other similar needs.
The Xhorse Multimeter is packed with diverse highlights.
- Comprehensive Functionality
It can be used to measure AC/DC voltage, AC/DC current, resistance, capacitance, frequency, duty cycle, diode and continuity.
It can also effectively achieve the following functions:
- Data Hold
Press the HOLD once to keep the test value displayed;
Press the HOLD again to release hold mode.
- Range Switching
Press RANGE to enter the manual range switching mode.
Press and hold the RANGE for 2s to exit the manual range and enter the automatic range mode.
- Screen Backlight Switch
Press LIGHT button once to turn on the screen backlight, and then press the LIGHT button again to turn off the scree backlight.
- Function Switching
When the function knob is switched to a multifunctional, press SELECT to select different measurement functions on the gear.
- Automatic Shutdown
During the measurement, if the range switch is not moved or the function button is not pressed for about 15 minutes, the multimeter will “automatically shut down” to save energy.
In the automatic shutdown state, pressing any button or turning the function knob can restart the multimeter.
- Leakage Detection
The featured fast detection function is providing a 3V DC power supply. It is accurate to 0.1μAand suitable for static leakage detection of electronic products, especially for remote leakage detection.
It can use the traditional multimeter method:
Insert the black and red leads into corresponding terminals and provide an external power supply for leakage detection.
New method:
- It can also adopt the fast detection method by inserting the red lead into the “LE+” terminal and the black lead into the “LE-” terminal.
- Switch the function knob to the leakage test gear “LE”.
- Measure directly without an external power supply, and read the current from the display screen for judgment.
- If OL is displayed, it indicates that the current exceeds the range(6mA) and the standby current is tool high.
(Normal Range: Wired Remote< 2μA, Wireless Remote< 10μA)
- Mistest Protection
It can withstand a maximum impact of 600V and equipped with overvoltage and overcurrent alarm prompts.
- Long Endurance
With an overall power consumption of less than 3mA and a long battery life.
- HD Large Screen
High-definition large screen LCD backlight display, more intuitive operational interaction, and keep the clear display in low-light environments.
- Exquisite Details
The design is easy to grip and can prevent slipping. The knob design conforms to user habits and is easy to rotate. The terminals are located at the front and the functional area is divided in shape to avoid interference. The rear support can be erected at a certain angle to meet various usage conditions.