Xhorse Dolphin XP005L Calibration Error Code 6 Solution

Problem:

One of our customers failed to calibrate the Xhorse Dolphin XP005L key cutting machine. The dolphin ii reported error code 6 during the calibration process.

Xhorse Dolphin Xp005l Calibration Error 6 Solution 1

Xhorse Dolphin Xp005l Calibration Error 6 Solution 2

Possible solution:

Open the back cover and adjust the X-axis sensor or baffle.

Xhorse Dolphin Xp005l Calibration Error 6 Solution 3

Xhorse Dolphin Xp005l Calibration Error 6 Solution 4

 

User feedback:

He checked and found this part is broken.

Xhorse Dolphin Xp005l Calibration Error 6 Solution 5

Final solution:

Need to replace the X-axis sensor.

Better replace the sensor of other axes to the X-axis and do an X-axis motor test first to see if there are any other problems.

Then send the test result to us.

 

www.vvdishop.com